Digital RS485 Interface Modbus COD Controller For Treated Water Digital RS485 Interface Modbus COD Controller For Treated Water Digital RS485 Interface Modbus COD Controller For Treated Water Digital RS485 Interface Modbus COD Controller For Treated Water Digital RS485 Interface Modbus COD Controller For Treated Water Digital RS485 Interface Modbus COD Controller For Treated Water

Large Image :  Digital RS485 Interface Modbus COD Controller For Treated Water

Product Details:
Place of Origin: China
Brand Name: Daruifuno
Certification: CE, ISO
Model Number: DUC2-COD-H-A
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Carton
Delivery Time: 5-25 days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 10000 Sets per Month

Digital RS485 Interface Modbus COD Controller For Treated Water

Description
Product Name: COD Meter Display Range: 0-1000mg/L
Relay Control: 2 Settable SPST Relays Analog Current Output: 2 Settable 0/4~20mA
Communication Method: Two-wire RS485 Interface OTA: Without
Configuration Information: Power Off Protection Time/Data Record: Record 14000 Historical Data
Protection Level: IP66 Shell Material: Enhanced ABS
High Light:

Digital COD Controller

,

Treated Water COD Controller

,

Digital COD Meter


Digital RS485 Interface Modbus COD/TOC/BOD Controller For Treated Water

 
DRFN water quality online analyzer can realize automatic online monitoring of chemical oxygen demand in water samples. The monitoring data and operating status of the instrument can be transmitted to the environmental monitoring and control center through the data acquisition instrument; the environmental monitoring and control center can also send counter-control instructions to control the instrument to complete the measurement, calibration and other processes. DRFN series instruments can be widely used in automatic monitoring stations, water plants, regional water boundary points, heavy metal monitoring of water quality in sewage discharge, and monitoring of water environment by environmental regulatory agencies at all levels.
 
Specification:

Model DUC2-COD-H-A
Software Version DRFN COD Analysis software V1.0
Sensor Input Compatible with all DRFN's COD Digital Sensors
Display Range 0-1000mg/L
Resolution 0.01 mg/L
Relay Control 2 settable SPST relays with a maximum load of 3A/250VAC
Analog Current Output 2 settable 0/4~20mA current outputs with a maximum load of 1000Ω
Communication Method

Two-wire RS485 interface
MODBUS RTU
support JSON text data format

OTA ——
Display Screen

128*64 black-and-white graphic lattice LCD
adjustable backlight mode
adjustable display rate

Configuration Information Power off protection, parameters are retained indefinitely
Time/Data Record

Year/month/day/hour/min/second, record 14000 historical data
record interval can be set between 1~999 minutes

Maintenance Records Last 100 times
Protection Level IP66
Operating Environment 0~60℃,RH<95% ( no condensation)
Storage Environment -20~70℃, RH<55% ( no condensation, precision instruments)
Shell Material Enhanced ABS
Dimension 144*144*120 mm
Mounting Method Wall mounting, pipe clamping, panel installation (hole size 138*138 mm)
Electrical Interface The back end reserved 3 M12*1.5 Gram head, line diameter 3~6.5 mm
Power Supply 100~240VAC
Power Consumption About 7W
Weight About 800g

 

Please click the user manual of RS485 COD controller here:

COD controller User Manual.pdf

 

Brief introduction:

● Compatible with all DRFN digital COD sensors;
● Separately have a list of controller and sensor settings for quick and detailed parameter setting;
● The working status of the sensor can be queried, including reading the serial number;
● Support a variety of installation methods;
● Time and historical data recording function;
● 3.2-inch large LCD screen;
● User-friendly Chinese and English language interface;
● Password can be set to prevent misoperation;
● 2 SPST multi-function and settable relays;
● Two 0/4~20mA active current loop outputs;
● RS485 interface, Modbus RTU communication protocol;
● IP66 waterproof level, sealed enclosure can isolate pollution and corrosive gas;

Digital RS485 Interface Modbus COD Controller For Treated Water 0
Aplication:
◇ Surface water
◇ Process water
◇ Sewage treatment plant
◇ Industrial wastewater
◇ Drinking water
◇ River

 
FAQ
1. Which sensors can be connected to your COD controller?

A: The COD meter can be compatible with DRFN digital COD sensors.
 
2. How does your COD controller collect sensor data?
A: The connected sensor uploads the detected data in a special encrypted communication method to ensure that the controller can collect high-precision data more stably

3. Does the COD controller have an ambient temperature alarm function?
Our COD controller has ambient temperature alarm function

4: Which parameter can be show on your COD controller?
Can measure parameters such as COD, TOC, turbidity and temperature;BOD can also be obtained and show on the COD controller. 
 